Skill Explorer

PROOFGRAPH / EVIDENCE NAVIGATION

Don’t just read my claims. Trace the evidence.

Ask where a skill was used, how a system was evaluated, or why an engineering decision was made.

Ask for ProofGraph Explorer

Deterministic answers from documented portfolio evidence

Evidence report5 sources · grounded response

Show me evidence of Model Evaluation

Here’s the evidence.

Poultry Disease Classification: VGG16 transfer learning with targeted fine-tuning; 94% validation accuracy across four categories. 94% Validation accuracy · local research. Four poultry disease categories; dataset identity and sample count not supplied. Four-class VGG16 transfer learning with targeted fine-tuning using TensorFlow/Keras. Validation accuracy across four classes; dataset size, split details, class names and external validation are not supplied. Sub-500 ms inference statement has no supplied hardware, percentile, sample size or production SLA definition. Swin Transformer for EEG Seizure Classification: Validated recording/annotation handling, filtering, segmentation, parameter estimation, reconstruction, fuzzy clustering and real-EEG FRP checks. Selected annotated TUSZ recordings. 19 EEG channels; delta/theta/alpha/beta/gamma filtering; non-overlapping 1-second seizure windows; per-segment AMI/FNN and signal-dependent fuzzy threshold; phase-space reconstruction and fuzzy C-means. Four-class segment discrimination remains challenging; accuracy is modest across bands. MYSZ has only one patient and is excluded from the patient-separated pilot. Only five held-out test patients; initial generalization pilot, not a definitive cross-patient performance estimate. Segment and patient results are not directly comparable: class sets, evaluation units and split strategies differ. Controlled CNN-vs-Swin patient-separated comparison is ongoing/planned; it has no supplied completed results. Internal Biomedical Sensors and Systems Lab, University of Memphis research; no public repository, publication URL or stable external artifact link is supplied. AutoCare Agent: Hybrid BM25 + all-MiniLM-L6-v2 dense retrieval evaluated across 100 diagnostic queries. 90% Recall@5 · local research. 100 diagnostic queries; 20 service manuals; approximately 4,500 document chunks. OpenSearch BM25 + all-MiniLM-L6-v2 dense embeddings through Sentence-Transformers. Decision-support POC, not a substitute for a certified technician. Recall describes the 100-query retrieval evaluation, not field diagnostic accuracy. Separate lexical/dense scores and scenario pass rates are not supplied. EEG Signal Processing & Classification: Sleep Spindle Detection and Motor Imagery Classification: Baseline CSP classifiers achieve approximately 61.5% / 61.7% mean session-wise LOSO accuracy. Baseline CSP + LDA and CSP + linear SVM mean LOSO accuracy. ~61.5% Baseline CSP + LDA LOSO accuracy · local research. PhysioNet EEG Motor Movement/Imagery: clean 106-subject baseline, sessions R04, R08 and R12. 8–30 Hz filtering; cue-locked epochs -1.0 to 4.0 s, baseline -1.0 to 0.0 s, classification window 0.5 to 3.5 s. Fit CSP on training folds only. Subject-wise Leave-One-Session-Out across R04, R08 and R12, avoiding random trial splits. Research workflows and benchmarks, not clinical diagnostic systems or production medical devices. EPCTL11 detection-count agreement is a calibration-participant result, not universal detection improvement or validated accuracy, sensitivity or specificity. EPCTL14 generalized well; EPCTL12 showed moderate over-sensitivity; EPCTL13 and EPCTL15 exposed cross-subject failure modes. Manual detections generally had shorter average durations than YASA. No aggregate cross-participant quality metric is supplied. S088, S092 and S100 were excluded because their 128 Hz recordings differed from the expected 160 Hz; the clean baseline contains 106 of 109 audited subjects. LOSO means Leave-One-Session-Out within subjects across R04, R08 and R12, not leave-one-subject-out or clinical performance. Tuning cohort size and uncertainty estimates are not separately supplied. Tuning yielded only about 1–1.2 percentage points of reported mean LOSO improvement; subject/session non-stationarity remained a larger constraint than classifier choice alone. ANPHY-Sleep / PhysioNet methods, metrics and artifact belong to this project, separately from Swin/FRP seizure classification on TUSZ. EEG Signal Processing & Classification: Sleep Spindle Detection and Motor Imagery Classification: Tuned CSP classifiers achieve approximately 62.7% / 62.4% mean session-wise LOSO accuracy. Tuned CSP + LDA and CSP + linear SVM mean LOSO accuracy; no inferred tuning cohort size. ~62.7% Tuned CSP + LDA LOSO accuracy · local research. PhysioNet EEG Motor Movement/Imagery left-vs-right motor imagery; tuning cohort size not separately supplied. 8–30 Hz filtering; cue-locked epochs -1.0 to 4.0 s, baseline -1.0 to 0.0 s, classification window 0.5 to 3.5 s. Fit CSP on training folds only. Subject-wise Leave-One-Session-Out across R04, R08 and R12, avoiding random trial splits. LDA: 6 CSP components, LSQR, shrinkage = 0.3. Linear SVM: 8 CSP components. Confusion matrices, CSP spatial patterns and CSV summaries inspected in a Streamlit experiment dashboard. Research workflows and benchmarks, not clinical diagnostic systems or production medical devices. EPCTL11 detection-count agreement is a calibration-participant result, not universal detection improvement or validated accuracy, sensitivity or specificity. EPCTL14 generalized well; EPCTL12 showed moderate over-sensitivity; EPCTL13 and EPCTL15 exposed cross-subject failure modes. Manual detections generally had shorter average durations than YASA. No aggregate cross-participant quality metric is supplied. S088, S092 and S100 were excluded because their 128 Hz recordings differed from the expected 160 Hz; the clean baseline contains 106 of 109 audited subjects. LOSO means Leave-One-Session-Out within subjects across R04, R08 and R12, not leave-one-subject-out or clinical performance. Tuning cohort size and uncertainty estimates are not separately supplied. Tuning yielded only about 1–1.2 percentage points of reported mean LOSO improvement; subject/session non-stationarity remained a larger constraint than classifier choice alone. ANPHY-Sleep / PhysioNet methods, metrics and artifact belong to this project, separately from Swin/FRP seizure classification on TUSZ.

direct evidenceModel evaluation

Poultry Disease Classification

VGG16 transfer learning with targeted fine-tuning; 94% validation accuracy across four categories.

Documented result94% validation accuracyFour-class model validation (local research; completed): Validation accuracy; split sizes and class labels are not supplied. Four poultry disease categories; dataset identity and sample count not supplied. Validation accuracy: 94%. Four-class validation accuracy; sample count and external validation not supplied. Validation accuracy across four classes; dataset size, split details, class names and external validation are not supplied. Sub-500 ms inference statement has no supplied hardware, percentile, sample size or production SLA definition.
direct evidenceResearch methodology

Swin Transformer for EEG Seizure Classification

Validated recording/annotation handling, filtering, segmentation, parameter estimation, reconstruction, fuzzy clustering and real-EEG FRP checks.

Documented resultValidated EEG → FRP pipelinePreprocessing / FRP pipeline validation (local research; completed): 19 EEG channels; delta/theta/alpha/beta/gamma filtering; non-overlapping 1-second seizure windows; per-segment AMI/FNN and signal-dependent fuzzy threshold; phase-space reconstruction and fuzzy C-means. Selected annotated TUSZ recordings. Four-class segment discrimination remains challenging; accuracy is modest across bands. MYSZ has only one patient and is excluded from the patient-separated pilot. Only five held-out test patients; initial generalization pilot, not a definitive cross-patient performance estimate. Segment and patient results are not directly comparable: class sets, evaluation units and split strategies differ. Controlled CNN-vs-Swin patient-separated comparison is ongoing/planned; it has no supplied completed results. Internal Biomedical Sensors and Systems Lab, University of Memphis research; no public repository, publication URL or stable external artifact link is supplied.
direct evidenceRetrieval evaluation

AutoCare Agent

Hybrid BM25 + all-MiniLM-L6-v2 dense retrieval evaluated across 100 diagnostic queries.

Documented result90% Recall@5100-query retrieval evaluation (local research; completed): Recall@5 for hybrid retrieval. 100 diagnostic queries; 20 service manuals; approximately 4,500 document chunks. Recall@5: 90%. Hybrid retrieval over 100 diagnostic queries; profile-supported, evaluation artifacts pending. Indexed document chunks: ~4,500. Approximate corpus size: 20 service manuals. Service manuals: 20. Indexed automotive service manuals. Decision-support POC, not a substitute for a certified technician. Recall describes the 100-query retrieval evaluation, not field diagnostic accuracy. Separate lexical/dense scores and scenario pass rates are not supplied.
direct evidenceResearch evaluation

EEG Signal Processing & Classification: Sleep Spindle Detection and Motor Imagery Classification

Baseline CSP classifiers achieve approximately 61.5% / 61.7% mean session-wise LOSO accuracy. Baseline CSP + LDA and CSP + linear SVM mean LOSO accuracy.

Documented resultBaseline CSP classifiers achieve approximately 61.5% / 61.7% mean session-wise LOSO accuracyMotor imagery baseline LOSO (local research; completed): 8–30 Hz filtering; cue-locked epochs -1.0 to 4.0 s, baseline -1.0 to 0.0 s, classification window 0.5 to 3.5 s. Fit CSP on training folds only. Subject-wise Leave-One-Session-Out across R04, R08 and R12, avoiding random trial splits. PhysioNet EEG Motor Movement/Imagery: clean 106-subject baseline, sessions R04, R08 and R12. Baseline CSP + LDA LOSO accuracy: ~61.5%. Baseline CSP + LDA; reported mean research LOSO accuracy. PhysioNet EEG Motor Movement/Imagery: clean 106-subject baseline, sessions R04, R08 and R12. Within-subject Leave-One-Session-Out (R04, R08, R12). Not a clinical or held-out-subject result. Baseline CSP + linear SVM LOSO accuracy: ~61.7%. Baseline CSP + linear SVM; reported mean research LOSO accuracy. PhysioNet EEG Motor Movement/Imagery: clean 106-subject baseline, sessions R04, R08 and R12. Within-subject Leave-One-Session-Out (R04, R08, R12). Not a clinical or held-out-subject result. Research workflows and benchmarks, not clinical diagnostic systems or production medical devices. S088, S092 and S100 were excluded because their 128 Hz recordings differed from the expected 160 Hz; the clean baseline contains 106 of 109 audited subjects. LOSO means Leave-One-Session-Out within subjects across R04, R08 and R12, not leave-one-subject-out or clinical performance. Tuning cohort size and uncertainty estimates are not separately supplied. Tuning yielded only about 1–1.2 percentage points of reported mean LOSO improvement; subject/session non-stationarity remained a larger constraint than classifier choice alone.
direct evidenceResearch evaluation

EEG Signal Processing & Classification: Sleep Spindle Detection and Motor Imagery Classification

Tuned CSP classifiers achieve approximately 62.7% / 62.4% mean session-wise LOSO accuracy. Tuned CSP + LDA and CSP + linear SVM mean LOSO accuracy; no inferred tuning cohort size.

Documented resultTuned CSP classifiers achieve approximately 62.7% / 62.4% mean session-wise LOSO accuracyMotor imagery tuned LOSO (local research; completed): 8–30 Hz filtering; cue-locked epochs -1.0 to 4.0 s, baseline -1.0 to 0.0 s, classification window 0.5 to 3.5 s. Fit CSP on training folds only. Subject-wise Leave-One-Session-Out across R04, R08 and R12, avoiding random trial splits. LDA: 6 CSP components, LSQR, shrinkage = 0.3. Linear SVM: 8 CSP components. Confusion matrices, CSP spatial patterns and CSV summaries inspected in a Streamlit experiment dashboard. PhysioNet EEG Motor Movement/Imagery left-vs-right motor imagery; tuning cohort size not separately supplied. Tuned CSP + LDA LOSO accuracy: ~62.7%. 6 CSP components, LSQR and shrinkage = 0.3; reported mean research LOSO accuracy. PhysioNet EEG Motor Movement/Imagery left-vs-right motor imagery; tuning cohort size not separately supplied. Within-subject Leave-One-Session-Out (R04, R08, R12). Not a clinical or held-out-subject result. Tuned CSP + linear SVM LOSO accuracy: ~62.4%. 8 CSP components, linear SVM; reported mean research LOSO accuracy. PhysioNet EEG Motor Movement/Imagery left-vs-right motor imagery; tuning cohort size not separately supplied. Within-subject Leave-One-Session-Out (R04, R08, R12). Not a clinical or held-out-subject result. Research workflows and benchmarks, not clinical diagnostic systems or production medical devices. S088, S092 and S100 were excluded because their 128 Hz recordings differed from the expected 160 Hz; the clean baseline contains 106 of 109 audited subjects. LOSO means Leave-One-Session-Out within subjects across R04, R08 and R12, not leave-one-subject-out or clinical performance. Tuning cohort size and uncertainty estimates are not separately supplied. Tuning yielded only about 1–1.2 percentage points of reported mean LOSO improvement; subject/session non-stationarity remained a larger constraint than classifier choice alone.